Item |
Characteristics |
Operating
Temperature Range(oC) |
-40~+85 |
Rated Voltage Range (V) |
6.3~50 |
Nominal
capacitance range (uF) |
0.1~100 |
Capacitance Tolerance(20oC,
120Hz) |
+/-20% |
Leakage Current (uA) |
I<=0.03CV+3 (at 20oC,after
5 minutes)
C:
Nominal Capacitance
(uF),
V: Rated Voltage (v) |
Dissipation
Factor(20oC, 120Hz) |
Rated
voltage (v) |
6.3 |
10 |
16 |
25 |
35 |
50 |
D.F. |
0.30 |
0.25 |
0.20 |
0.15 |
|
Load
Life(+85oC) |
Time |
1000hours.(Polarity
inverts for every 250 hours) |
Leakage
current |
Not
more than the specified value. |
Capacitance
change |
within+/-20%
of the initial value |
Dissipation |
Not
more than 200% of the specified value. |
|
Shelf
Life(+85oC) |
Time |
500hours. |
Leakage
current |
Not
more than the specified value. |
Capacitance
change |
within+/-20%
of the initial value |
Dissipation |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for 30 minutes,24~48
hours before measurement |