Item
|
Characteristics
|
Operating Temperature Range(oC) |
-40~+85(250-450WV:-25~+85) |
Rated Voltage Range (V) |
16~450 |
Nominal capacitance range (uF) |
39~22000 |
Capacitance Tolerance(20oC,120Hz) |
+/-20% |
Leakage current
(uA) |
I<=0.01CV or 1.5mA whichever is smaller (at20oC
,after 5 minutes)
C: Nominal Capacitance (uF) V: Rated Voltage (V) |
Dissipation Factor(20oC,120Hz) |
Rated voltage (v) |
16 |
25 |
35 |
50 |
63 |
80 |
100 |
160-450 |
D.F. (MAX) |
0.50 |
0.40 |
0.35 |
0.30 |
0.25 |
0.20 |
0.20 |
0.15 |
|
Load Life(+85oC) |
Time |
3000 hours |
Leakage Current |
Not more than the specified value. |
Capacitance Change |
Within
+/-20% of the initial value. |
Dissipation Factor |
Not more than 200% of the specified value. |
|
Shelf Life(+85oC) |
Time |
500 hours |
Leakage Current |
Not more than the specified value. |
Capacitance Change |
Within
+/-20% of the initial value. |
Dissipation Factor |
Not more than 200% of the specified value. |
After test: Rated voltage to be applied for 60 minutes, 24
to 48 hours before measurement
|