Item |
Characteristics |
Operating
Temperature Range(oC) |
-40~+85 |
-25~+85 |
Rated Voltage Range (V) |
10~100 |
160~450 |
Nominal
capacitance range (uF) |
1800~82000 |
180~2200 |
Capacitance
Tolerance(20oC,120Hz) |
+/-20%
|
Leakage current (uA) |
I<=0.01CV(
uA)
or 1.5mA whichever is smaller (at 20oC,
after 5 minutes)
C: Nominal Capacitance (uF) V: Rated Voltage (V) |
Dissipation
Factor(20oC,120Hz)
|
Rated
voltage (v)
|
10-16 |
25 |
35-50 |
63 |
80-100 |
Cap (uF) |
<=2700 |
- |
- |
0.20 |
0.15 |
0.15 |
3300-4700 |
- |
0.35 |
0.25 |
0.20 |
0.15 |
5600-6800 |
0.40 |
0.35 |
0.30 |
0.20 |
0.20 |
>=8200 |
0.40 |
0.35 |
0.35 |
0.25 |
- |
Rated
voltage (v)
|
160-200 |
250-450 |
D=35 |
0.12 |
0.15 |
|
Temperature
Stability(120Hz) |
Rated
voltage (v) |
10 |
16-35 |
50-100 |
160-200 |
250-400 |
450 |
Impedance
Ratio |
Z-25oC/Z+20oC |
5 |
4 |
3 |
3 |
4 |
4 |
Z-40oC/Z+20oC |
18 |
15 |
10 |
6 |
8 |
- |
|
Load
Life(+85oC) |
Time |
2000
hours |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20%
of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
|
Shelf
Life(+85oC) |
Time |
500
hours |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20%
of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
After test :
Rated voltage
to be applied for 60 minutes, 24 to 48 hours before measurement.
|