Item |
Characteristics |
Operating
Temperature Range(oC) |
-55~+105 |
-40~+105 |
-25~+105 |
Rated Voltage Range (V) |
6.3~100 |
160~400 |
450 |
Nominal
capacitance range (uF) |
0.47~15000 |
Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
Leakage
current (uA) |
6.3~100V
I<=0.03 or 4
(Whichever is greater)
C: Nominal Capacitance (uF) V: Rated Voltage (V) |
160~450V
CV<=1000: I<=0.1CV+40
CV>1000: I<=0.04CV+100
C: Nominal Capacitance (uF) V: Rated Voltage (V) |
Dissipation
Factor(20oC,120Hz) |
Rated Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
315~350 |
400~450 |
D.F. |
0.22 |
0.19 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
0.15 |
0.20 |
0.25 |
when nominal
capacitance is over 1000uF D.F. shall be added
0.02 to the listed
value with increase of every 1000 uF
|
Temperature Stability(120Hz) |
Rated Voltage (V) |
6.3~100 |
160~200 |
250 |
315~350 |
400 |
450 |
Impedance Ratio |
Z-40oC/Z+20oC |
- |
3 |
3 |
4 |
6 |
15 |
Z-25oC/Z+20oC |
- |
4 |
6 |
8 |
10 |
- |
|
Load
Life(+105oC) |
Time |
3000 hours(D=5,6.3,8:
2000hrs). |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
|
Shelf
Life(+105oC) |
Time |
1000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for