Item |
Characteristics |
Operating
Temperature Range(oC) |
-40~+105 |
-25~+105 |
Rated Voltage Range (V) |
10~100 |
160~250 |
Nominal
capacitance range (uF) |
4.7~3300 |
Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
Leakage
current (uA) |
I<=0.01CV (at 20oC ,after 2minutes)
C: Nominal Capacitance (uF) V: Rated Voltage (V)
|
I<=0.03CV (at 20oC
,after 2minutes)
C: Nominal Capacitance (uF) V: Rated Voltage (V) |
Dissipation
Factor(20oC,120Hz) |
Rated
Voltage (V) |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
D.F. |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
0.15 |
when nominal
capacitance is over 1000uF D.F. shall be added
0.02 to the listed
value with increase of every 1000 uF
|
Temperature Stability(120Hz) |
Rated Voltage (V) |
10~16 |
25~100 |
160 |
250 |
Impedance Ratio |
Z-40oC/Z+20oC |
5 |
4 |
- |
- |
Z-25oC/Z+20oC |
- |
- |
4 |
7 |
|
Load
Life(+105oC) |
Time |
1000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
|
Shelf
Life(+105oC) |
Time |
500
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for
30 minutes, 24 to 48 hours before measurement.
|