Item |
Characteristics |
Operating Temperature
Range(oC) |
-55~+105 |
-40~+105 |
Rated Voltage Range (V) |
6.3~100 |
160~400 |
Nominal
capacitance range (uF) |
0.1~15000 |
0.47~220 |
Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
Leakage current (uA) |
I<=0.01CV
or 3 whichever is greater.
( at 20oC,after 2 minutes)
|
CV<=1000,
I<=0.1CV+40; CV>1000,
I<=0.04CV+100
(
at 20oC,after 1 minutes)
|
C: Nominal capacitance (uF)
V: Rated voltage (V)
|
Dissipation Factor(20oC,120Hz) |
Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
350~400 |
D.F. |
0.22 |
0.19 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
0.15 |
0.20 |
when nominal
capacitance is over 1000uF D.F. shall be added 0.02 to the
listed
value with increase of every 1000 uF |
Temperature Stability(120Hz) |
Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160 |
200 |
250 |
350~400 |
Impedance
Ratio |
Z-25oC/Z+20oC |
4 |
3 |
2 |
3 |
Z-40oC/Z+20oC |
8 |
6 |
4 |
3 |
8 |
6 |
|
Load Life(+105oC) |
Time |
2000
hours(D=5~D=8: 1000hrs). |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
|
Shelf Life(+105oC) |
Time |
1000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
After test: Rated voltage to be applied for 30 minutes,
24 to 48 hours before measurement.
|