Item |
Characteristics |
Operating Temperature Range(oC) |
-40~+105 |
Rated Voltage Range (V) |
200~400 |
Nominal capacitance range (uF) |
1~33 |
Capacitance Tolerance(20oC,120Hz) |
+/-20%
|
Leakage current (uA) |
I<=0.03CV
or 4 whichever is greater. |
CV<=1000:I<=0.1CV+40
CV>1000:I<=0.04CV+100 |
C: Nominal Capacitance
(uF) V: Rated Voltage (V)
|
Dissipation Factor(20oC,120Hz) |
Rated
voltage (v) |
200 |
250 |
400 |
D.F. |
0.09 |
0.09 |
0.10 |
|
Load Life(+105oC) |
Time |
2000
hours |
Leakage current |
Not
more than the specified value. |
Capacitance Change |
within +/-20% of the initial value. |
Dissipation Factor |
Not
more than 200% of the specified value. |
|
Shelf Life(+105oC) |
Time |
1000
hours |
Leakage current |
Not more than the
specified value. |
Capacitance Change |
within +/-20% of the initial value. |
Dissipation Factor |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for 30 minutes,24 to