Item |
Characteristics |
Operating
Temperature Range(oC) |
-40~+105 |
-25~+105 |
Rated Voltage Range (V) |
6.3~100 |
160~450 |
Nominal
capacitance range (uF) |
0.1~10000 |
0.47~220 |
Capacitance
Tolerance(20oC,120Hz) |
20% |
Leakage
current (uA) |
0.01CV or 3 whichever is greater.
C:
Nominal V: Rated voltage (V)
|
0.02CV+15
C: Nominal V: Rated
voltage (V)
|
Dissipation
Factor(20oC,120Hz) |
Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~400 |
450 |
D.F. |
0.25 |
0.20 |
0.17 |
0.15 |
0.12 |
0.10 |
0.10 |
0.08 |
0.20 |
0.25 |
when nominal
capacitance is over 1000uF D.F. shall be added
0.02 to the listed
value with increase of every 1000 uF
|
Load
Life(+105oC) |
Time |
2000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
|
Shelf
Life(+105oC) |
Time |
1000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
After test: Rated voltage to be applied for
30 minutes, 24 to 48 hours before measurement.
|