Item |
Characteristics |
Operating
Temperature Range(o C) |
-55-+105 |
Rated Voltage Range (V) |
6.3~63 |
Nominal
capacitance range (uF) |
0.1~220 |
Capacitance
Tolerance(20o C, 120Hz) |
+/-20% |
Leakage
Current (uA) |
I<=0.01CV or 3uA
whichever is greater, (at 20o C,after 2 minutes)
C: Nominal Capacitance
(uF), V: Rated Voltage ( v) |
Dissipation Factor(20o C, 120Hz) |
Rated
voltage (v) |
6.3 |
10 |
16 |
16 |
25 |
35 |
50~63 |
D.F. |
0.22 |
0.19 |
0.16 |
0.14 |
0.14 |
0.12 |
0.10 |
|
Temperature
stability (120Hz) |
Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50~63 |
Impedance
Ratio |
Z-25o C/Z+20o C |
3 |
2 |
Z-40o C/Z+20o C |
8 |
5 |
4 |
3 |
|
Load
Life(+105o C) |
Time |
2000hours |
Leakage
current |
Initial
specified value or less |
Capacitance
change |
within+/-20%
of initial value |
Dissipation |
Not
more than 200% of the specified value. |
|
Shelf
Life (+105o C) |
Time |
1000hours |
Leakage
current |
Initial
specified value or less |
Capacitance
change |
within+/-20%
of initial value |
Dissipation |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for 60 minutes,
24 to 48 hours before measurement.
|