Item |
Characteristics |
Operating
Temperature Range(oC) |
-40~+85 |
Rated Voltage Range (V) |
6.3~450 |
Nominal
capacitance range (uF) |
0.1~22000 |
Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
Leakage
current (uA) |
Rated
Voltage (V) |
6.3~100 |
160~450 |
|
I<=0.01CV or
3 whichever is greater.( at 20oC,after 2 minutes) |
I<=0.03CV+10
(at 20oC,after 2 minutes ) |
C: Nominal capacitance (uF)
V: Rated voltage (V) |
Dissipation
Factor(20oC,120Hz) |
Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
350~450 |
D.F. |
0.22 |
0.19 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
0.18 |
0.20 |
when nominal
capacitance is over 1000uF D.F. shall be added
0.02 to the listed
value with increase of every 1000 uF
|
Temperature
Stability(120Hz) |
Rated
Voltage (V) |
6.3 |
10 |
16~50 |
63 |
100 |
160 |
200 |
250 |
350 |
400 |
450 |
Impedance
Ratio |
Z-25oC/Z+20oC |
|
|
|
|
|
6 |
8 |
8 |
15 |
Z-40oC/Z+20oC |
8 |
6 |
4 |
3 |
3 |
|
|
|
Load
Life(+85oC) |
Time |
2000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
|
Shelf
Life(+85oC) |
Time |
1000
hours. |
Leakage
Current |
Not
more than the specified value. |
Capacitance
Change |
Within
+/-20% of the initial value. |
Dissipation
Factor |
Not
more than 200% of the specified value. |
After test: Rated voltage to be applied for
30 minutes, 24 to 48 hours before measurement.
|